| Author | 
            Message | 
        
        
			| 
				
				 KingCobra 
				Moderator 
				
					 Joined: Mon Jan 28, 2013 7:40 pm Posts: 2891 Location: Illinois
				 
				 
			 | 
			
				
				
					
						 Safety Siren Pro Series 3 Digital Radon Gas Detector
  How far off were yours from each other when tested side-by-side?
  If you can believe it, I never tested both my radon detectors side-by-side before. The other day I took the one from upstairs and put it downstairs on the other side of the basement from the other. One reads 3.0 and the other reads 4.5 so not I moved them side-by-side to see what I get as a reading. 
					
						_________________MY OUTSIDE RADIATION MONITORING STATION:South Beloit, Illinois - GMC200 Outside on HEPA air purifier,  ground level, facing West. http://netc.com/chart/view.php?n=1%3AEB5A139C 
					
  
			 | 
		
		
			| Wed Jan 30, 2013 4:38 pm | 
			
				
					 
					
					 
				  
			 | 
    	
		
	
	
		  | 
	
	
			| 
				
				 hey 
				Site Admin 
				
					 Joined: Mon Jan 28, 2013 6:51 pm Posts: 743 Location: Arkansas
				 
				 
			 | 
			
				
				
					
						I just moved them together today.  I should reset them and wait 2 days.    
					
  
			 | 
		
		
			| Wed Jan 30, 2013 5:10 pm | 
			
				
					 
					
					 
				  
			 | 
    	
		
	
	
		  | 
	
	
			| 
				
				 KingCobra 
				Moderator 
				
					 Joined: Mon Jan 28, 2013 7:40 pm Posts: 2891 Location: Illinois
				 
				 
			 | 
			
				
				
					
						 I didn't reset mine, I will just have to leave them there long enough to allow for a complete change. 
					
						_________________MY OUTSIDE RADIATION MONITORING STATION:South Beloit, Illinois - GMC200 Outside on HEPA air purifier,  ground level, facing West. http://netc.com/chart/view.php?n=1%3AEB5A139C 
					
  
			 | 
		
		
			| Thu Jan 31, 2013 2:12 am | 
			
				
					 
					
					 
				  
			 | 
    	
		
	
	
		  | 
	
	
			| 
				
				 hey 
				Site Admin 
				
					 Joined: Mon Jan 28, 2013 6:51 pm Posts: 743 Location: Arkansas
				 
				 
			 | 
			
				
				
					
						 I did not reset the two unit and the reading were dropping over the last week but they were off   6.6 and 18.7 
					
  
			 | 
		
		
			| Thu Jan 31, 2013 10:43 am | 
			
				
					 
					
					 
				  
			 | 
    	
		
	
	
		  | 
	
	
			| 
				
				 KingCobra 
				Moderator 
				
					 Joined: Mon Jan 28, 2013 7:40 pm Posts: 2891 Location: Illinois
				 
				 
			 | 
			
				
				
					
						 I just checked mine and they say 3.2 & 4.5 so I will keep watching them over the next few days to see any change. 
					
						_________________MY OUTSIDE RADIATION MONITORING STATION:South Beloit, Illinois - GMC200 Outside on HEPA air purifier,  ground level, facing West. http://netc.com/chart/view.php?n=1%3AEB5A139C 
					
  
			 | 
		
		
			| Thu Jan 31, 2013 3:41 pm | 
			
				
					 
					
					 
				  
			 | 
    	
		
	
	
		  | 
	
	
			| 
				
				 KingCobra 
				Moderator 
				
					 Joined: Mon Jan 28, 2013 7:40 pm Posts: 2891 Location: Illinois
				 
				 
			 | 
			
				
				
					
						 I just checked my two radon detectors again and now the one is still 4.5 pCi/L (as expected) and the other one that I moved from upstairs to the basement (still sitting right next to the other one in the basement) now reads 4.4 pCi/L so I am impressed! I will give it a few more days to see if it will reach the 4.5 level. I have no way to prove 100% that the true level of radon in my basement is 4.5 pCi/L but I can safely say these two radon detectors are calibrated the same. 
					
						_________________MY OUTSIDE RADIATION MONITORING STATION:South Beloit, Illinois - GMC200 Outside on HEPA air purifier,  ground level, facing West. http://netc.com/chart/view.php?n=1%3AEB5A139C 
					
  
			 | 
		
		
			| Tue Feb 05, 2013 2:49 pm | 
			
				
					 
					
					 
				  
			 | 
    	
		
	
	
		  | 
	
	
			| 
				
				 KingCobra 
				Moderator 
				
					 Joined: Mon Jan 28, 2013 7:40 pm Posts: 2891 Location: Illinois
				 
				 
			 | 
			
				
				
					
						 The test results are in from checking to see how close my two radon detectors are calibrated. 
					
						
  
						Attachments: 
						
						
			File comment: Test results from checking to see how close my two radon detectors are calibrated.
		
			 
			2013-02-06_10-48-26_988.jpg [ 232.9 KiB | Viewed 109247 times ]
		
		
	 
						
						 
					
						_________________MY OUTSIDE RADIATION MONITORING STATION:South Beloit, Illinois - GMC200 Outside on HEPA air purifier,  ground level, facing West. http://netc.com/chart/view.php?n=1%3AEB5A139C 
					
			 | 
		
		
			| Wed Feb 06, 2013 12:03 pm | 
			
				
					 
					
					 
				  
			 | 
    	
		
	
	
		  | 
	
	
			| 
				
				 hey 
				Site Admin 
				
					 Joined: Mon Jan 28, 2013 6:51 pm Posts: 743 Location: Arkansas
				 
				 
			 | 
			
				
				
					
						 lucky,  mine are .3 difference. 
					
  
			 | 
		
		